Maximum squeeze on a hand dynamometer, both hands. The best-studied strength marker in ageing research.

Method
Dynamometer · both hands, best of 6
Equipment
Hand dynamometer
Attempts
3, best counts
Reference
Clinical norm

Protocol

  1. Stand, arm by your side, elbow straight. Use the same device and routine every quarter.

  2. Squeeze as hard as you can for 3 seconds. Alternate hands: three squeezes each, a minute between squeezes on the same hand.

  3. Enter every squeeze. The best of either hand is your result, and the gap between hands is shown.

Safety. Do not hold your breath and strain. Stop if your wrist hurts. Rest 1 min between attempts.

How it is scored

Scored against British pooled centiles (Dodds 2014), interpolated for your exact age. Those data are the best of several squeezes, mostly on hydraulic or spring dynamometers; one squeeze reads lower and digital devices can read a few kg higher, so keep the same device and routine every quarter.

Clinical norm

Scored against a published reference table for your age and sex, with the table named.

Reference table

Grip strength across the life course: normative data from twelve British studies (Dodds et al., PLOS ONE 2014)

Year
2014
Sample
49,964 people
Who
49,964 people aged 4–90 in 12 British studies; centiles by exact age and sex
Sexes
Women and men

Best of several squeezes, mostly both hands, on hydraulic or spring dynamometers. Protocol matters as much as the device: one squeeze reads lower, and electronic devices can read 4–5 kg higher. Use the same device and routine every quarter. The authors say these cross-sectional centiles should not be used to track one person’s change.

Shown for comparison, never scores

Hand grip strength: normative reference values for 18- to 85-year-olds in the United States (Wang et al., JOSPT 2018)

Year
2018
Sample
1,232 people
Who
1,232 US adults, NIH Toolbox; calibrated digital Jamar, seated, elbow at 90°, one squeeze per hand
Sexes
Women and men

Shown for comparison only. Its medians run 0–9 kg below Dodds in men aged 30–59, with 17–109 people per age group.

Reference lines shown with the result

  • Galpin floor: men 40 kg · women 35 kgAndy Galpin, Huberman Lab Guest Series ep. 1 (Jan 2023): at least 40 kg for men, about 35 kg for women. On Perform ep. 2 (Jun 2024) he gave over 45 kg and over 28 kg.
  • Weakness cut-off: men 26 kg · women 16 kgFNIH sarcopenia project (Studenski 2014): under 26 kg for men and 16 kg for women. EWGSOP2 (2019): under 27 and 16 kg.

Change that is just noise

A change smaller than 2 kg is treated as noise (the app’s rule; no published kg figure, devices differ by 4–5 kg). The percentile is shown as a likely range: where the result would rank one such step lower and one higher.

Also worked out from this result

The gap between hands

You squeeze with both hands, so the app shows the best of each and the gap between them: one minus the weaker hand over the stronger.

A gap over 10% is flagged, and one over 20% more strongly, following Andy Galpin (Huberman Lab, January 2023), who calls more than 20% “probably bad”. These are one coach’s stated lines, not a published norm.

Limits of the reference

What the source cannot tell you, and where the app has had to make a choice the source did not make.

  • Dodds’s centiles are cross-sectional: different people at each age. They understate how fast one person declines, so the line is a floor, not a forecast. The authors say the centiles should not be used to track one person’s change; the app tracks change from your own results.
  • Electronic dynamometers can read 4–5 kg above the hydraulic and spring devices most of the reference data were collected on. Use the same device every quarter.